{"id":51,"date":"2012-09-30T16:12:56","date_gmt":"2012-09-30T20:12:56","guid":{"rendered":"http:\/\/adc-dao.com\/wordpress\/?p=51"},"modified":"2015-09-17T11:10:46","modified_gmt":"2015-09-17T15:10:46","slug":"compatibilite-des-versions","status":"publish","type":"post","link":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/","title":{"rendered":"Compatibilit\u00e9 des versions"},"content":{"rendered":"<p>Bonjour,<\/p>\n<p>Dans mon dernier article nous avons \u00e9crit notre premi\u00e8re routine en VB .Net. Nous l&rsquo;avons \u00e9crite en utilisant Visual Studio 2010 et cibl\u00e9 la version 2012 d&rsquo;AutoCAD. Avez-vous tent\u00e9 de charger le DLL dans une autre version d&rsquo;AutoCAD en utilisant la command Netload? Dans la version 2011 ou 2010 vous avez s\u00fbrement eu un message indiquant que le DLL utilisait une version plus r\u00e9cente du \u00abruntime\u00bb. Quant \u00e0 la version 2013, aucun message d&rsquo;erreur n&rsquo;apparait mais la commande n&rsquo;est pas reconnue.<\/p>\n<p>Commen\u00e7ons par les versions ant\u00e9rieures (2010 ou 2011). Ces versions d&rsquo;AutoCAD utilisent la version 3.5 du \u00abframework\u00bb .Net. Pour cr\u00e9er des applications pour ces versions, nous aurions pu utiliser Visual Studio 2008 qui cible par d\u00e9faut cette version, mais nous pouvons tous simplement recompiler en utilisant une version ant\u00e9rieur du \u00abframework\u00bb.<\/p>\n<p><!--more--><\/p>\n<p>Ouvrez Visual Studio 2010 puis chargez la solution <strong>HelloWorld<\/strong>. \u00c0 partir de l&rsquo;explorateur de solution, double-cliquez sur <strong>My project<\/strong>. Choisissez ensuite la section <strong>Compiler<\/strong>.<\/p>\n<p><a href=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-53\" title=\"Version Framework 1\" src=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png\" alt=\"\" width=\"1728\" height=\"935\" srcset=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png 1728w, http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1-300x162.png 300w, http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1-1024x554.png 1024w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/a><\/p>\n<p>Ensuite, cliquez le bouton<strong> Options avanc\u00e9es de compilation&#8230;.<\/strong><\/p>\n<p>Dans la bo\u00eete de dialogue <strong>Param\u00e8tres avanc\u00e9es de compilation<\/strong>, vous trouverez une liste d\u00e9roulante indiquant la version cible du \u00abframework\u00bb. Modifiez la version pour 3.5 au lieu de 4.<\/p>\n<p><a href=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-54\" title=\"Version Framework 2\" src=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-2.png\" alt=\"\" width=\"830\" height=\"575\" srcset=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-2.png 830w, http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-2-300x207.png 300w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/a><\/p>\n<p>Visual Studio vous indiquera qu&rsquo;il faut fermer la solution et l&rsquo;ouvrir \u00e0 nouveau pour appliquer les changements. Faites-le.<\/p>\n<p>D\u00e9marrer le d\u00e9bogage (F5) ou fl\u00e8che verte dans la barre d&rsquo;outils. Le d\u00e9bogage utilise la version 2012 comme nous l&rsquo;avions configur\u00e9. Vous verrez, l&rsquo;application sera fonctionnelle.<\/p>\n<p>Apr\u00e8s avoir v\u00e9rifi\u00e9 que ADCHW fonctionne bien. G\u00e9n\u00e9rez la version finale (menu d\u00e9roulant <em>G\u00e9n\u00e9rer-&gt;G\u00e9n\u00e9rer HelloWorld<\/em>)<em>.<\/em> Charger le DLL cr\u00e9\u00e9 dans la version 2010 ou 2011 et vous verrez que tout est fonctionnel. Pour les versions 2007, 2008 ou 2009, le \u00abframework\u00bb utilis\u00e9 \u00e9tait la version 2.0 (Visual Studio 2005). Donc, recompiler l&rsquo;application HelloWorld avec le\u00a0 \u00abframework\u00bb 2.0 permettrait de l&rsquo;ex\u00e9cuter sur les version 2007, 2008 et 2009. Par contre pour des applications plus complexes, il faut toujours se m\u00e9fier et v\u00e9rifier que toutes les fonctionnalit\u00e9s de l&rsquo;application sont disponibles dans les diff\u00e9rentes versions du \u00abframework\u00bb ou d&rsquo;AutoCAD.<\/p>\n<p>Pour la version 2013, c&rsquo;est un peu diff\u00e9rent. Cette version utilise toujours le \u00abframework\u00bb version 4 mais les fichiers de r\u00e9f\u00e9rence ont chang\u00e9s. Nous devons donc apporter quelques modifications \u00e0 notre application.<\/p>\n<p>Fermez la solution courante. Je sugg\u00e8re aussi de copier le dossier de l&rsquo;application sous le nom <strong>HelloWorld2013<\/strong>. Ouvrez la solution <strong>HelloWorld<\/strong> \u00e0 partir du dossier que vous venez de copier. Apporter les modifications suivantes au projet (My Project):<\/p>\n<ul>\n<li>Ajustez le framework cible \u00e0 la version 4 (section <strong>Compiler<\/strong>, bouton <strong>Options avanc\u00e9es de compilation&#8230;<\/strong>);<\/li>\n<li>Changer le programme de d\u00e9bogage (section <strong>D\u00e9boguer<\/strong>, <strong>D\u00e9marrer le programme externe<\/strong>) pour d\u00e9marrer la version 2013 en mode de d\u00e9bogage;<\/li>\n<li>Dans la section <strong>R\u00e9f\u00e9rences<\/strong>, supprimez les r\u00e9f\u00e9rences <em>acmgd.dll<\/em> et <em>acdbmgd.dll<\/em>;<\/li>\n<li>Ajoutez les 2 m\u00eames r\u00e9f\u00e9rences mais \u00e0 partir du dossier de la version 2013 et aussi le fichier <em>accoremgd.dll<\/em>.<\/li>\n<\/ul>\n<p><a href=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Migrating-2013.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-56\" title=\"Migrating 2013\" src=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Migrating-2013.png\" alt=\"\" width=\"578\" height=\"452\" srcset=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Migrating-2013.png 578w, http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Migrating-2013-300x234.png 300w\" sizes=\"auto, (max-width: 578px) 100vw, 578px\" \/><\/a><\/p>\n<p>N&rsquo;oubliez par de mettre la propri\u00e9t\u00e9 \u00abCopie locale\u00bb \u00e0 <strong>False<\/strong> pour ces 3 r\u00e9f\u00e9rences.<\/p>\n<p><a href=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Rererences-2013.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-58\" title=\"Rererences 2013\" src=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Rererences-2013.png\" alt=\"\" width=\"1293\" height=\"261\" srcset=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Rererences-2013.png 1293w, http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Rererences-2013-300x60.png 300w, http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Rererences-2013-1024x206.png 1024w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/a><\/p>\n<p>D\u00e9marrez le d\u00e9bogage et charger le DLL. N&rsquo;oubliez pas qu&rsquo;il sera dans le nouveau dossier <strong>HelloWorld2013\\..\\Debug<\/strong>. Tout devrait bien fonctionner. Vous pourrez ensuite compiler votre version finale.<\/p>\n<p>Pour plus de d\u00e9tails sur la migration vous pouvez consulter le blogue de <strong>Through the Interface<\/strong> de Kean Walmsley qui est toujours excellent. Voici le lien directe pour l&rsquo;article <a title=\"Migrating .NET application to work with AutoCAD 2013\" href=\"http:\/\/through-the-interface.typepad.com\/through_the_interface\/2012\/03\/migrating-net-applications-to-work-with-autocad-2013.html\" target=\"_blank\">Migrating .NET applications to work with AutoCAD 2013<\/a>.<\/p>\n<p>Dans un prochain article, nous explorerons les diff\u00e9rentes m\u00e9thodes pour afficher des messages.<\/p>\n<p>Bonne programmation!!!!<\/p>\n<p>Andr\u00e9<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Bonjour, Dans mon dernier article nous avons \u00e9crit notre premi\u00e8re routine en VB .Net. Nous l&rsquo;avons \u00e9crite en utilisant Visual Studio 2010 et cibl\u00e9 la version 2012 d&rsquo;AutoCAD. Avez-vous tent\u00e9 de charger le DLL dans une autre version d&rsquo;AutoCAD en utilisant la command Netload? Dans la version 2011 ou 2010 vous avez s\u00fbrement eu un &hellip; <\/p>\n<p class=\"link-more\"><a href=\"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/\" class=\"more-link\">Continuer la lecture<span class=\"screen-reader-text\"> de &laquo;&nbsp;Compatibilit\u00e9 des versions&nbsp;&raquo;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-51","post","type-post","status-publish","format-standard","hentry","category-introduction"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Compatibilit\u00e9 des versions - Blogue ADC-DAO<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Compatibilit\u00e9 des versions - Blogue ADC-DAO\" \/>\n<meta property=\"og:description\" content=\"Bonjour, Dans mon dernier article nous avons \u00e9crit notre premi\u00e8re routine en VB .Net. Nous l&rsquo;avons \u00e9crite en utilisant Visual Studio 2010 et cibl\u00e9 la version 2012 d&rsquo;AutoCAD. Avez-vous tent\u00e9 de charger le DLL dans une autre version d&rsquo;AutoCAD en utilisant la command Netload? Dans la version 2011 ou 2010 vous avez s\u00fbrement eu un &hellip; Continuer la lecture de &laquo;&nbsp;Compatibilit\u00e9 des versions&nbsp;&raquo;\" \/>\n<meta property=\"og:url\" content=\"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/\" \/>\n<meta property=\"og:site_name\" content=\"Blogue ADC-DAO\" \/>\n<meta property=\"article:published_time\" content=\"2012-09-30T20:12:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2015-09-17T15:10:46+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png\" \/>\n<meta name=\"author\" content=\"Andr\u00e9 Dagenais\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Andr\u00e9 Dagenais\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#article\",\"isPartOf\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/\"},\"author\":{\"name\":\"Andr\u00e9 Dagenais\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/#\\\/schema\\\/person\\\/30c434ee2fe6b91acb878ee61119cf52\"},\"headline\":\"Compatibilit\u00e9 des versions\",\"datePublished\":\"2012-09-30T20:12:56+00:00\",\"dateModified\":\"2015-09-17T15:10:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/\"},\"wordCount\":614,\"commentCount\":0,\"image\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/wp-content\\\/uploads\\\/2012\\\/09\\\/Version-Framework-1.png\",\"articleSection\":[\"Introduction VB .Net\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/\",\"url\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/\",\"name\":\"Compatibilit\u00e9 des versions - Blogue ADC-DAO\",\"isPartOf\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#primaryimage\"},\"image\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/wp-content\\\/uploads\\\/2012\\\/09\\\/Version-Framework-1.png\",\"datePublished\":\"2012-09-30T20:12:56+00:00\",\"dateModified\":\"2015-09-17T15:10:46+00:00\",\"author\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/#\\\/schema\\\/person\\\/30c434ee2fe6b91acb878ee61119cf52\"},\"breadcrumb\":{\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#primaryimage\",\"url\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/wp-content\\\/uploads\\\/2012\\\/09\\\/Version-Framework-1.png\",\"contentUrl\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/wp-content\\\/uploads\\\/2012\\\/09\\\/Version-Framework-1.png\",\"width\":\"1728\",\"height\":\"935\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/compatibilite-des-versions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Compatibilit\u00e9 des versions\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/#website\",\"url\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/\",\"name\":\"Blogue ADC-DAO\",\"description\":\"Personnalisation et programmation AutoCAD\\\/Revit\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/#\\\/schema\\\/person\\\/30c434ee2fe6b91acb878ee61119cf52\",\"name\":\"Andr\u00e9 Dagenais\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/87d05f96d9500d9db4f8ab6ae1d8595c048e2e089694944af6f7ee77fe75de14?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/87d05f96d9500d9db4f8ab6ae1d8595c048e2e089694944af6f7ee77fe75de14?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/87d05f96d9500d9db4f8ab6ae1d8595c048e2e089694944af6f7ee77fe75de14?s=96&d=mm&r=g\",\"caption\":\"Andr\u00e9 Dagenais\"},\"url\":\"http:\\\/\\\/adc-dao.com\\\/wordpress\\\/author\\\/andred\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Compatibilit\u00e9 des versions - Blogue ADC-DAO","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/","og_locale":"fr_FR","og_type":"article","og_title":"Compatibilit\u00e9 des versions - Blogue ADC-DAO","og_description":"Bonjour, Dans mon dernier article nous avons \u00e9crit notre premi\u00e8re routine en VB .Net. Nous l&rsquo;avons \u00e9crite en utilisant Visual Studio 2010 et cibl\u00e9 la version 2012 d&rsquo;AutoCAD. Avez-vous tent\u00e9 de charger le DLL dans une autre version d&rsquo;AutoCAD en utilisant la command Netload? Dans la version 2011 ou 2010 vous avez s\u00fbrement eu un &hellip; Continuer la lecture de &laquo;&nbsp;Compatibilit\u00e9 des versions&nbsp;&raquo;","og_url":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/","og_site_name":"Blogue ADC-DAO","article_published_time":"2012-09-30T20:12:56+00:00","article_modified_time":"2015-09-17T15:10:46+00:00","og_image":[{"url":"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png","type":"","width":"","height":""}],"author":"Andr\u00e9 Dagenais","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Andr\u00e9 Dagenais","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#article","isPartOf":{"@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/"},"author":{"name":"Andr\u00e9 Dagenais","@id":"http:\/\/adc-dao.com\/wordpress\/#\/schema\/person\/30c434ee2fe6b91acb878ee61119cf52"},"headline":"Compatibilit\u00e9 des versions","datePublished":"2012-09-30T20:12:56+00:00","dateModified":"2015-09-17T15:10:46+00:00","mainEntityOfPage":{"@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/"},"wordCount":614,"commentCount":0,"image":{"@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#primaryimage"},"thumbnailUrl":"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png","articleSection":["Introduction VB .Net"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#respond"]}]},{"@type":"WebPage","@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/","url":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/","name":"Compatibilit\u00e9 des versions - Blogue ADC-DAO","isPartOf":{"@id":"http:\/\/adc-dao.com\/wordpress\/#website"},"primaryImageOfPage":{"@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#primaryimage"},"image":{"@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#primaryimage"},"thumbnailUrl":"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png","datePublished":"2012-09-30T20:12:56+00:00","dateModified":"2015-09-17T15:10:46+00:00","author":{"@id":"http:\/\/adc-dao.com\/wordpress\/#\/schema\/person\/30c434ee2fe6b91acb878ee61119cf52"},"breadcrumb":{"@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#primaryimage","url":"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png","contentUrl":"http:\/\/adc-dao.com\/wordpress\/wp-content\/uploads\/2012\/09\/Version-Framework-1.png","width":"1728","height":"935"},{"@type":"BreadcrumbList","@id":"http:\/\/adc-dao.com\/wordpress\/compatibilite-des-versions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"http:\/\/adc-dao.com\/wordpress\/"},{"@type":"ListItem","position":2,"name":"Compatibilit\u00e9 des versions"}]},{"@type":"WebSite","@id":"http:\/\/adc-dao.com\/wordpress\/#website","url":"http:\/\/adc-dao.com\/wordpress\/","name":"Blogue ADC-DAO","description":"Personnalisation et programmation AutoCAD\/Revit","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/adc-dao.com\/wordpress\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"http:\/\/adc-dao.com\/wordpress\/#\/schema\/person\/30c434ee2fe6b91acb878ee61119cf52","name":"Andr\u00e9 Dagenais","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/87d05f96d9500d9db4f8ab6ae1d8595c048e2e089694944af6f7ee77fe75de14?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/87d05f96d9500d9db4f8ab6ae1d8595c048e2e089694944af6f7ee77fe75de14?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/87d05f96d9500d9db4f8ab6ae1d8595c048e2e089694944af6f7ee77fe75de14?s=96&d=mm&r=g","caption":"Andr\u00e9 Dagenais"},"url":"http:\/\/adc-dao.com\/wordpress\/author\/andred\/"}]}},"_links":{"self":[{"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/posts\/51","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/comments?post=51"}],"version-history":[{"count":20,"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/posts\/51\/revisions"}],"predecessor-version":[{"id":303,"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/posts\/51\/revisions\/303"}],"wp:attachment":[{"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/media?parent=51"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/categories?post=51"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/adc-dao.com\/wordpress\/wp-json\/wp\/v2\/tags?post=51"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}